Control error displays – Alto-Shaam QC2-3 User Manual

Page 31

Advertising
background image

Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 2 9 .

T I T l e

T r o U b l e S h o o T I n G

conTrol error DISplayS

control

display

action

required

real Time clock bad

E-60: REAL TIME CLOCK DEFAULTS LOADED,
VERIFY CORRECT TIME, POWER CYCLE UNIT TO
CLEAR THIS MESSAGE.

This is likely caused by the unit having been unplugged for an extended

amount of time. The data stored in the Real-Time Clock has been reset to

the factory default values. Contact service if problem persists.

real Time clock not Detected

E-61: REAL TIME CLOCK NOT DETECTED.
POWER CYCLE UNIT AND CALL FOR
SERVICE IF THE PROBLEM PERSISTS.

Real Time Clock not detected. Contact service if problem persists.

button Stuck

E-90: BUTTON STUCK. CHECK ALL BUTTONS AND
ERROR WILL CLEAR WHEN THE PROBLEM HAS
BEEN RESOLVED

This error message indicates that a button is stuck. Check all buttons.

Error will clear when the problem has been solved. Contact service is

problem persists.

Using Default function values

E-80 - EEPROM ERROR
USING DEFAULT FUNCTION VALUES

This error message indicates the control memory is not correctly reading

user-set values. The Quickchiller will remain operational but the user

defined settings will be reloaded to the default values. The control will

revert to factory default settings and will require operator modification

each time the unit is used. Call Service. Acknowledge error by pressing the

power button.

probe open/Shorted

PROBE N

* OPEN -OR- PROBE N* SHORTED

CALL FOR SERVICE

This error message indicates a problem with the probe identified within the

display. The Quickchiller will operate normally in the Time mode but will

not operate in the Probe mode. Call service.
*N signifies probe number that is shorted: 1= top, 2= middle, 3= bottom

cavity open Shorted

CAVITY SENSOR OPEN OR SHORTED.
CALL FOR SERVICE

This error message indicates a problem with the interior cavity sensor. The

Quickchiller will not operate in any operational mode. Call service.

coil open Shorted

COIL N

* OPEN OR COIL N* SHORTED

CALL FOR SERVICE

This error message indicates a problem with the display identified coil

sensor. The Quickchiller will remain operational but will extend the defrost

cycle to the full period of 20 minutes. Call service.
*N signifies coil number that is shorted.

bad calibration

E-81: BAD CALIBRATION. PLEASE CALL SERVICE
AD1-0

=(PASS) (FAIL) AD1-1=(PASS)(FAIL)

AD2-0

=(PASS)(FAIL) AD2-1=(PASS)(FAIL)

AD3-0

=(PASS)(FAIL) AD3-1=(PASS)(FAIL)

Calibration bad. Call service.

note: Display will signify PASS where calibration is good, or FAIL

where calibration is bad.

requires calibration

E-82: REqUIRES CALIBRATION.
PLEASE CALL SERVICE

Requires Calibration. Call service.

power failure

POWER WAS OFF FOR HH:MM
PRESS PROGRAM TO ACKNOWLEDGE

Power has been off. Press Program to acknowledge.
notE: if such an event has occurred, it is strongly recommended

that you ensure the food is safe for consumption according to

local health regulations.

Advertising
This manual is related to the following products: