Q U I C K C H I L L E R • I N S T A L L A T I O N / O P E R A T I O N / S E R V I C E M A N U A L • 1 3 .

T I T l e

o p e r a T I o n

chIll proceSSInG cycleS

The Alto-Shaam Quickchiller uses high

velocity cold air circulation to remove heat from
prepared foods for the purpose of rapidly reducing
temperatures through the danger zone and
providing maximum storage life. Cold air is evenly
directed across each pan from the control side of
every Quickchiller model to assure rapid cooling.

The high velocity cold air produced by the

Quickchiller removes insulating layers of warm
moist air that surrounds hot products. The rapid
removal of these insulating layers of heat reduces
food temperatures significantly faster than any
other method of temperature reduction and
provides enhanced food safety.

Because the basic performance of the

Quickchiller relies on high velocity air movement
around each container of food, it is important to
load the food by placing pans directly into the pan
slides. Always use the pan slides to support the
edges of 12" x 20" steam table pans (GN 1/1). Use
a wire shelf for pan support when using 18" x 26"
sheet pans; 12" x 10" steam table pans (GN 1/2);
loaf pans; entree plates; and other small containers.

QUIckchIller operaTIon MoDeS

proceSSInG WITh The USe of probeS

Probe usage provides chill or frozen food

processing activation and termination through

use of a food probe or probes inserted into the

center of the food. The cycle is automatically

terminated when the center of the food reaches

the probe sensing temperature set by the

operator. In units with multiple probes, all

probes much reach the sensing temperature set

by the operator to trigger automatic termination

of the cycle.

proceSSInG by TIMe

The time mode provides processing activation

and termination based on a timed cycle selected

by the operator. Upon expiration of the timed

cycle, the cabinet automatically reverts to the

designated holding cycle temperature.

holDInG

Following processing completion, a holding

cycle maintains the temperature to safely

hold foods after processing. The holding cycle

will also maintain a holding compartment

temperature between processing cycles.

InITIal QUIckchIller operaTIon

prechIllInG The cabIneT

The Quickchiller should be prechilled prior

to placing hot foods into the cabinet. In models

equipped with an optional roll-in cart (trolley),

always maintain an empty food cart inside the

chiller when prechilling to eliminate air loss

through the bottom of the chiller cabinet door. An

optional Prechill Sealing Strip (Item #

SA-35079

)

may also be used for this purpose.

Optional Prechill Sealing Strip

SA-35079

c a u t i o n

TO MAINTAIN SANITATION
CONTROL, ALL FOODS FOR
QUICK-CHILL OR QUICK-FREEZE
PROCESSING MUST BE AT A
TEMPERATURE ABOVE 140°F (60°C)
AND MUST BE TIGHTLY COVERED.