Front USB Connections

Non-incendive equipment (keyboards, mouse) are permitted for use on the
Industrial Personal Computer (Associated Non-incendive Field Wiring Apparatus)
front USB 5. In addition to being non-incendive, any equipment connected to the
front USB 5 must satisfy the following criteria.

The figure shows the USB cable wiring:

Notes:

1. The following table gives the Non-incendive Circuit Parameters:

The Entity Concept allows interconnection of non-incendive apparatus with
associated apparatus – not specifically examined combinations – as a system when
the approved values of V

oc

(or U

o

) and I

sc

(or I

o

) for the associated apparatus are

less than or equal to Vmax (U

i

) and Imax (I

i

) for the non-incendive apparatus, and

the approved values of C

a

(C

o

) and L

a

(L

o

) for the associated apparatus are greater

than or equal to C

i

+ C

cable

and L

i

+ L

cable

, respectively, for the non-incendive field

wiring apparatus.

2. Non-incendive field wiring apparatus shall satisfy the following:

Circuit Parameters

USB port 5
(front USB)

Open-circuit voltage = V

oc

4.96 V

Short-circuit current = I

sc

1180 mA

Associated capacitance = C

a

20

F

Associated inductance = L

a

3.21

H

Industrial Personal Computer Asso-
ciated Non-incendive Field Wiring
Apparatus

-

Non-incendive Field Wiring Apparatus
(Mouse, Keyboard)

V

oc

I

sc

C

a

L

a




V

max

I

max

C

i

+ C

cable

L

i

+ L

cable

USB cable

Associated Non-incendive