1 pl-3600t series, 1 pl-3600t series -9 – Proface APL3000B - Node Box PC User Manual

Page 100

Advertising
background image

Chapter 5 Installation and Wiring

5-9

5.2

Installing/removing the front module and the control box

Before operating the internal switches or replacing the backlight or the batteries for clock data backup,

remove the control box from the front module.

5.2.1

PL-3600T Series

„ Removing the front module and the control box

Remove the control box from the front module with the following steps:

(1)

Unscrew the attachment screw securing the flexible cable cover and remove the cover.

Be sure to confirm that power is not being supplied to the PL unit before installing or

removing the front module and the control box. Failure to do so can result in an electric

shock.

• In the Soft OFF status, power is supplied to some of the circuits even when the

screen of the front module is blank. Before removing the control box, be sure to

confirm that its power supply switch is OFF or its power cable is not connected.

• Use a screwdriver to loosen or tighten the screws. Be sure not to tighten screws

too tightly, since it may damage the unit.

• When removing or replacing screws, be careful that they do not fall inside the PL

unit’s chassis.

Flexible Cable Cover

Advertising