Chapter 3 Specifications

3-13

„ RAS Interfaces

D-sub 9 pin socket connector

• Be sure to use only the rated voltage level when using pin #1 (DC+12V) for

external power output. Failure to do so can lead to a unit malfunction or accident.

Interfit Bracket

#4-40 (UNC)

Pin Arrangement

Pin No.

Signal Name

Description

1

+12 V

Output Current: 100mA or less
Output Voltage: DC12V±5%

2

DOUT0(+)

Data out 0(+)

3

DOUT1(+)

Data out 1(+)

4

DIN0(+)

Data in 0(+)

5

DIN1(+)

Data in 1(+)

*1

*1

Can be used for inputting the reset signals.

6

GND

Ground

7

DOUT0(-)

Data out 0(-)

8

DOUT1(-)

Data out 1(-)

9

DINCOM

Data in common