„ Serial Mode Select Switch

Switch

No.

Description

ON

OFF

RS-232C RS-422

RS-485

(The data is not

automatically

controlled via

the RS (RTS)

signal.)

*3

RS-485

(The data is

automatically

controlled via

the RS (RTS)

signal.)

*3

1

Internal
setting

Reserved

Reserved

OFF

*1

*1

Be sure to leave these settings OFF.

OFF

*1

OFF

*1

OFF

*1

2

Changes
COM1’s
communication
method

RS-422/
RS-485

RS-232C

OFF

ON

ON

ON

3

Changes
COM1’s
communication
method

RS-422/
RS-485

RS-232C

OFF

ON

ON

ON

4

Changes
SD(TXD)
data’s output
mode

SD(TXD) data
output is
controlled via
the RS(RTS)
signal.

SD(TXD) data
output is NOT
controlled via the
RS(RTS) signal.
(normally output)

OFF

ON/
OFF

ON

OFF

5

Switches the
SD(TXD)
termination
resistance ON/
OFF

Inserts
termination
resistance of
220

Ω between

SDA and SDB.

No termination OFF

ON

ON/OFF

*2

*2

If you use the termination resistance, base your settings on the connection specifications.

*3

This setting determines whether or not the SD (TXD) output driver is automatically con-

trolled via the RS (RTS) signal.

ON/OFF

*2

6

Switches the
RD(RXD)
termination
resistance ON/
OFF

Inserts
termination
resistance of
220

Ω between

RDA and RDB.

No termination OFF

ON

ON/OFF

*2

ON/OFF

*2

7

Switches the
shorting of
SDA and RDA
ON or OFF

Shorts SDA
and RDA
(RS-485 mode)

No shorting

(RS-422 mode)

OFF

OFF

ON

ON

8

Switches the
shorting of
SDB and RDB
ON or OFF

Shorts SDB
and RDB
(RS-485 mode)

No shorting

(RS-422 mode)

OFF

OFF

ON

ON

9

RS(RTS)
Automatic
control mode
(enabled only
when RS-485
mode)

The data is
automatically
controlled via
the RS(RTS)
signal.

The data is not
automatically
controlled via the
RS(RTS) signal.

OFF

OFF

OFF

ON

10

OFF

OFF

OFF

ON

Advertising