Proface APL3000B - Node Box PC User Manual

Page 117

Advertising
background image

PL3000 Series Hardware Manual

5-26

Wiring

When connecting the power cord, use the following items. (Made by Phoenix Contact

*1

.)

Power Connector (Right-angle Screw) Specifications

Connecting the Power Cord

(1)

Confirm that the power is not supplied to the PL unit.

(2)

Loosen three screws in the center of the power connector.

(3)

Strip the membrane of the power cord, twist the wire ends, and connect them to the power connector.

(4)

Attach the Power Connector to the PL and fix it to the PL main unit with right/left tightening screws.

Recommended Driver

SZF 1-0.6x3.5 (1204517)

Recommended Pin Terminals

AI 0.75-8GY (3200519)
AI 1-8RD (3200030)
AI 1.5-8BK (3200043)
AI 2.5-8BU (3200522)

Recommended Pin Terminal Crimp Tool

CRIMPFOX ZA3 (1201882)

*1

For details, please contact your local Phoenix Contact distributor.

+

24V

0V

FG

FG Grounding Terminal connected to
the PL

• Use a flat-blade screwdriver (Size 0.6 X 3.5) to tighten the terminal screws.

The torque required to tighten these screws is 0.5 to 0.6 N

•m [5-7 lb•in.].

• Do not solder the cable connection. Doing so may damage the unit due to

abnormal heat or cause a fire.

FG

+

Insertion
Direction

+

FG

Advertising