Chapter 5 Installation and Wiring

5-3

For easier maintenance, operation, and improved ventilation, be sure to install the PL at least 50mm
[1.97in.] away from adjacent structures and other equipment. 120mm [4.72in.] space (minimum) is neces-
sary at the front for cable curve.

Be sure that the surrounding air temperature and the ambient humidity are within their specified ranges.
Check the surrounding air temperature 30mm [1.18in.] away from the main unit.

Be sure that heat from surrounding equipment does not cause the PL to exceed its standard operating tem-
perature.