PL3000 Series Hardware Manual

3-14

‹ General Purpose Signal Input (DIN 0, 1)

Input Voltage

DC12V to 24V

Input Method

Sink / Source Input

Input Current

10mA ( DC24V )

Input Resistance

3.6k

Input Points

2 points ( common with external
reset input )

Operation
Range

ON voltage

DC10V or more

OFF voltage

DC3V or less

Isolation Method

Photocoupler Isolation

Dielectric Strength Voltage

500V or more

• General-Purpose Input (DIN) level must be 1.5 seconds or longer to be detected.

It may not detect under 1.5 seconds.

• Be sure the voltage value between terminals is controlled via the input voltage, so

that the PL is operated within its recommended range. If the input voltage

exceeds this range, a malfunction or PL damage may occur.

• With Sink/Source input, even if the DIN(-), and RESET(-) are positive, and

DIN(+), RESET(+) are negative, no problems are created. Be sure to operate the

unit within the recommended voltage range.

+5V

1.8k

1/10W

1.8k

1/10W

R

PC357

No polarity - for Sink /
Source input

switch or other
switching device

Cable

DC12V
to 24V

DINCOM pin

#

9

DIN0(+) pin

#

4

DIN1(+) pin

#

5

(Interface Circuit)

R