2 pl-3600*/pl-3700*/pl-3900t series, 2 pl-3600, Pl-3700∗/pl-3900t series -5 – Proface APL3000B - Node Box PC User Manual

Page 96

Advertising
background image

Chapter 5 Installation and Wiring

5-5

5.1.2

PL-3600

∗/PL-3700∗/PL-3900T Series

This section describes the procedures and precautions for installing the PL units.

„ Check the Installation Gasket’s Seating

It is strongly recommended that you use the installation gasket, since it absorbs vibration in addition to

repelling liquids.

For the gasket installation procedure, see “6.3 Replacing the Installation Gasket (page 6-5)”.

„ Creating a Panel Cut

Create the correct sized opening required to install the PL, using the installation dimensions given.

SEE

6.3 Replacing the Installation Gasket (page 6-5)

• Before installing the PL into a cabinet or panel, check that the installation gasket

is securely attached to the unit.

• A gasket which has been used for a long period of time may have scratches or

dirt on it, and could have lost much of its dust and drip resistance. Be sure to

change the gasket periodically (or when scratches or dirt become visible).

SEE

PL-3600T Series

4.2.4 Panel Cut Dimensions (page 4-11)

PL-3600K Series

4.3.4 Panel Cut Dimensions (page 4-15)

PL-3700T Series

4.4.4 Panel Cut Dimension (page 4-20)

PL-3700K Series

4.5.4 Panel Cut Dimension (page 4-24)

PL-3900T Series

4.6.4 Panel Cut Dimensions (page 4-28)

Check that the installation panel or cabinet’s surface is flat, in good condition and has no

jagged edges.

• Panel thickness should be from 1.6mm [0.06 in.] to 10.0mm [0.29 in.]. Even if

panel thickness is within recommend range for "Panel Cut Dimensions", the

panel could warp, depending on panel's material and installation location of PL or

other devices. To prevent panel warpage, the installation surface may need to be

strengthened.

Advertising