Appendix A: OptiLogic Technical Specifications

Pointe Controller User Guide

296

This tab is used to configure two variables that are required to enter data
through the numeric keypad on the OL3850 panel.

Data Value – When the user inputs a numeric value and presses the

ENTER key on the keypad, the value is saved to Data Value. Mapped to a
32-bit Real Input tag (%IF).

To configure Data Value, click the

to the right and select a tag from

the pop-up menu. Each tag can be used only once.

Data Available – When the user inputs a numeric value and presses the
ENTER key on the keypad, the Data Available flag is set. Mapped to an
Input Bit tag (%IX).

To configure Data Available, click the

to the right and select a tag

from the pop-up menu. Each tag can be used only once.

For more information on entering data through the numeric keypad, see

Operator Panel Commands

on page 333.

When you have finished configuring the panel, click OK to save your changes and
close the window.