Appendix A: OptiLogic Technical Specifications
Pointe Controller User Guide
296
This tab is used to configure two variables that are required to enter data
through the numeric keypad on the OL3850 panel.
Data Value – When the user inputs a numeric value and presses the
ENTER key on the keypad, the value is saved to Data Value. Mapped to a
32-bit Real Input tag (%IF).
To configure Data Value, click the
to the right and select a tag from
the pop-up menu. Each tag can be used only once.
Data Available – When the user inputs a numeric value and presses the
ENTER key on the keypad, the Data Available flag is set. Mapped to an
Input Bit tag (%IX).
To configure Data Available, click the
to the right and select a tag
from the pop-up menu. Each tag can be used only once.
For more information on entering data through the numeric keypad, see
Operator Panel Commands
on page 333.