Appendix C: Ladder Diagram Block Reference

Pointe Controller User Guide

354

Functional Description

This block always passes the Enable input state (EN) through to the Enable Out
output state (ENO) without change; when EN becomes on, ENO is turned on, and
when EN becomes off, ENO is turned off.

When EN becomes on, the block function is executed and the following
conditions are evaluated in order:

1. If the Reset input (R) is true, then the Counter Value output (CV) is reset

to 0.

2. If R is false and the Count Up input (CU) is true, then CV is incremented

by 1.

3. If CV is greater than or equal to the Preset Value input (PV), then the

Output Up bit (QU) is set to true. If CV is less than PV, then QU is set to
false.

The block function is executed every time the ladder is

scanned

, so long as EN

remains on.

NOTE: Because the frequency of the count is based on the project’s

Scan Interval

,

it should not be used to gauge real time. To gauge real time, use a

Timer

.

Configuration Reference

The parameters of this block are described in the following table:

Param

Name

Config

Var Type

Description

EN

Enable

no

-

The state of the rung (off/on)
received from the left.

ENO

Enable
Out

no

-

The state of the rung (off/on)
passed to the right.

CU

Count Up

req

%IX

%QX

%MX

T_DONE

The enable bit which must be set in
order for the counter to increment.

R

Reset

req

%IX

%QX

%MX

T_DONE

The reset bit; if this bit is set, then
the counter is set to 0.

PV

Preset
Value

req

%IUD

%QUD

%MUD

Numeric

The preset or target value of the
counter.

QU

Output
Up

req

%QX

%MX

The “done” bit which is set when
the counter reaches the preset
value.