Rl/ft5000 – Triton FT5000XP PC-BASED ATMS User Manual User Manual

Page 186

Advertising
background image

A-2

M

ODEL

RL/FT5000

XP

U

SER

M

ANUAL

E

NTERING

THE

C

OMBINATION

The electronic lock combination consists of six digits. Upon arrival, the combina-
tion of the lock should already be set at 1-2-3-4-5-6. After installation of the unit

has been completed, perform the following steps:

1.

Enter the preset combination and check for proper operation. After each
keypress, the lock will beep. After the final digit has been entered, the lock
will beep twice and the open period will begin.

2.

When a valid combination has been entered, the operator will have
approximately 4 seconds to open the lock.

3.

To open the lock, turn the dial clockwise.

4.

After the lock is opened, the door may be opened.

L

OCKOUT

F

EATURE

The lock includes a WRONG TRY PENALTY lockout feature that prevents entry
from unauthorized personnel. This feature performs as follows:

Entry of four (4) consecutive invalid combinations starts a 5-minute delay
period.
-

LED flashes red at ten (10) second intervals.

At the end of the delay period, two (2) more consecutive invalid combinations

will restart an additional 5-minute delay.

C

HANGING

THE

C

OMBINATION

To change the combination of the lock, simply follow these directions.

1.

Enter six zeros.

2.

Enter the current combination (initially set at 1-2-3-4-5-6).

3.

Enter the new six (6) digit combination twice.

-

If a mistake is made, wait thirty (30) seconds and repeat the first 3
steps.

4.

Test lock combination several times before closing the door. The combination
is now changed.

Valid Code Entry - Double signal after valid six (6) digit code is entered.

Invalid Code Entry - Triple signal and old code is still valid.