Rl/ft5000 – Triton FT5000XP PC-BASED ATMS User Manual User Manual

Page 46

Advertising
background image

2 6

M

ODEL

RL/FT5000

XP

U

SER

M

ANUAL

V

ERIFY

O

PERATION

1.

Close and lock the security cabinet.

2.

Verify the cassettes are <Locked> in the dispenser.

3.

In Management Functions, select D

IAGNOSTICS

, then C

ASH

D

ISPENSER

.

4.

Select the T

EST

D

ISPENSE

option. Enter # of notes to be dispensed (1-5) from

the individual cassettes that are installed (“A”, “B”, “C”,or “D”). Select
P

ERFORM

T

EST

. The Test Dispense operation will start.

5.

The Test Dispense command instructs the dispenser to dispense, minimum,
one note from each installed and operational cassette into the reject cassette.
This test exercises the dispenser without sending notes to the exit.

6.

After completion of the Test Dispense, the following prompt is displayed
(Figure 4-20).

Figure 4-19. Enter # of notes.