KYORITSU 5000 Instruction Manual User Manual

Page 13

Advertising
background image

― 11 ―

Step2: Confirmation and change of set value

Confirm the mark indicating the
selected recording mode.
Refer to "5. Recording modes and
conditions

" in this manual to change

the recording mode or condition
(Recording interval/ Preset current
value).

Recording

mode

Details

Refer to:

Intermittent measured value is recorded
continuously at the preset interval.
(15-kind: 1 sec. to 60 min.)

P.16

When the preset current value is exceeded ,

(hereinafter, this event is referred as

current detection) three previous RMS

value, the RMS value when detecting it,

and four subsequent RMS values, 8 data in

total (0.8 sec.) are recorded.

P.19

The max. RMS value is recorded at every

10 sec. prior to and subsequent to the

current detection. It ends when a value

drops to 50% or less of the preset current

value; or when 10 min. has been elapsed.

P.21

Ten to twelve waveforms (for 200mS) are
recorded prior to and subsequent to the
current detection.

P.23

Continuous
recording

Event recording

Max. value
Recording

C a p t u r e
recording

Advertising