External communication specification, 1) general specifi cation, 2) interface specifi cation – Dwyer PSX2 User Manual

Page 160: Support software, Bulletin f-9-pux2

Advertising
background image

151

13. EXTERNAL COMMUNICATION SPECIFICATION

(1) General specifi cation

Item

Specifi cation

Transmission scheme

Half duplex

Synchronization scheme

Asynchronous

Transmission rate

500kBPS

Parity

Odd parity

Start/stop bit

1 bit

Data length

8 bits

Station

0, fi xed

Number of connectable units

1 unit

Transmission code

Hexadecimal value (MODBUS RTU mode)

Error detection

CRC-16

Echo back

None

Flow control

Xon/off

(2) Interface specifi cation

Electrical specifi cation: Conforms to USB standard.

Cable length: 3 m or less

Conforming cable: Mini USB cable

Connection scheme: 1:1 connection

„ Support software

Loader software for PC is provided as standard.
• Main function: To display and change main unit parameters (site setup), and to acquire mea-

sured data.
It is capable of importing instantaneous fl ow rate, instantaneous fl uid velocity, integrated
value, error information, wave receiving level and others.

Bulletin F-9-PUX2

Advertising