2 how to mount a small size sensor (z method), Bulletin f-9-pux2 – Dwyer PSX2 User Manual

Page 54

Advertising
background image

45

8.4.2 How to mount a small size (standard) sensor (Z method)

(1) Remove saddle set screws at 4 loca-

tions, and remove a saddle and a sen-
sor unit out of the frame.
Also, remove a saddle on the guide rail
for small size sensor (option).

Element holder

Lock nut

Saddle

Scale

Curser

Frame

BNC connector

Guide rail for small size sensor

(2) Mount the removed sensor unit on the

guide rail for small size sensor.
Fasten the sensor unit with mounting
dimension (L).

Mounting
dimension (L)

(3) Spread silicone grease over the whole

transmitting surface of the sensor.

Turn the element holder counterclock-
wise to return the sensor.
After cleaning the surface of the pipe,
the sensor should be mounted.

Element holder

Silicone grease

Transmitting surface

(4) Mount each sensor individually on the

marking line.

Front view

Back view

Upper side of

the marking line

Bottom side of

the marking line

Bulletin F-9-PUX2

Advertising
This manual is related to the following products: