8.6

How to mount high temperature sensor to pipe

8.6.1 How to mount a sensor (V method)

(1) Loosen the lock nut and slide the sensor so

as to meet the mounting dimension and then
tighten the nut.

BNC connect

Element holder

Lock nut

Saddle

Cursor

Frame

Scale

Mounting
dimension
(L)

(2) Apply a coat of grease for high temperature to

the transmitting surface of the sensor. Spread
the compound over the entire area.
Keep the sensor retracted by turning the ele-
ment holder counterclockwise.
After cleaning the surface of the pipe, the sen-
sor should be mounted.

High temperature
grease

Spatula

Transmission
unit

(3) Fix the both ends (saddles) of the sensor to

the pipe by stainless belts.

Stainless belt

Stainless belt

(4) Make sure the sensor is mounted in parallel

with the pipe axis and the mounting dimen-
sion is right. Then, turn the element holder
clockwise until the sensor comes in close
contact with the pipe.
Stop turning the element holder when it stiff-
ens because the transmitting surface comes in
contact with the pipe surface. Be careful not
to turn the holder excessively.

Element
holder

Cable

CAUTION

Be careful not to cut your hands or etc. by the
stainless belt.