Location requirements, Warning – Alliance Laundry Systems TMB795C User Manual

Page 20

Advertising
background image

Installation

M414905

18

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Location Requirements

The tumbler must be installed on a level floor. Floor

covering materials such as carpeting or tile should be

removed.
To assure compliance, consult local building code

requirements. The tumbler must not be installed or

stored in area where it will be exposed to water and/or

weather.

IMPORTANT: DO NOT block the airflow at the

rear of the tumbler with laundry or other articles.

Doing so would prevent adequate air supply to the

combustion chamber of the tumbler.

A typical tumbler enclosure is shown in Figure 1. Note

the minimum and maximum dimensions. Local codes

and ordinances must be complied with.

IMPORTANT: Install tumblers with sufficient

clearance for servicing and operation, refer to

Figure 1.

Figure 1

WARNING

To reduce the risk of serious injury, install

lockable door(s) to prevent public access

to rear of tumblers.

W055

TMB2131N

NOTE: Shaded areas indicate adjacent structure.

1

0.5 in. (13 mm) recommended between machines for removal or installation

2

Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim.

3

4 in. (102 mm) maximum header thickness

4

12 in. (305 mm) minimum clearance permitted for remainder

5

Guard

6

Provision for make-up air

7

24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes

8

0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed

TMB2131N

3

1

4

5

6

7

2

WARNING

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible

construction must conform to the minimum clearances.

W056

8

Advertising