Adjustments, Gas burner air shutter, Warning – Alliance Laundry Systems TMB795C User Manual

Page 57

Advertising
background image

55

M414905

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Adjustments

Gas Burner Air Shutter

NOTE: Air inlet shutters on the burner must be

adjusted so sufficient air is metered into the system

for proper combustion and maximum efficiency.

Before adjusting the inlet shutters be sure that all

lint is removed from lint compartments and lint

screen.

Air shutter adjustments will vary from location to

location and will depend on the vent system, number

of units installed, make-up air and line gas pressure.

Opening the shutter increases the amount of primary

air supplied to the burner while closing the shutter

decreases the primary air supply. Adjust air shutter as

follows:
Refer to Figure 25.

1. Open the access panel.
2. Start the tumbler and check the flame pattern. If

the flame pattern is straight up, insufficient air is

flowing through the tumbler and airflow switch is

improperly set. A flame pattern that flares to the

right and left indicates no air is flowing through

the tumbler. Correct air and gas mixture is

indicated if the flame pattern is primarily blue,

with small yellow tips, and bends to the right of

the heater section. Too little air is indicated if the

flame if yellow, lazy and smokey.

3. To adjust the air shutter, loosen air inlet shutter

adjusting screw.

4. Open or close air shutter as necessary to obtain

proper flame intensity.

5. After air shutter is adjusted for proper flame,

tighten air shutter adjusting screw securely.

Figure 25

WARNING

To reduce the risk of electric shock, fire,

explosion, serious injury or death:

• Disconnect electric power to the

tumbler before servicing.

• Close gas shut-off valve to gas tumbler

before servicing.

• Close steam valve to steam tumbler

before servicing.

• Never start the tumbler with any guards/

panels removed.

• Whenever ground wires are removed

during servicing, these ground wires

must be reconnected to ensure that the

tumbler is properly grounded.

W002

T457I

1

Air Shutter Adjusting Screws

T457I

1

PROPER AIRFLOW

INSUFFICIENT AIRFLOW

NO AIRFLOW

1

1

Advertising