Adjustments

M414905

56

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Airflow Switch

Gas and Electric Tumblers

The airflow switch (located on the rear of tumbler,

Figure 26) is set at the factory for proper operation.

However, if there is a problem with the switch, it

should be adjusted as follows:

Confirm exhaust duct and make-up air vents are

properly sized and not obstructed. Refer to

Make-Up Air and Venting sections.

Confirm lint screen is clean and access panels are

in place.

Check operation of airflow switch and adjust as

follows:

NOTE: Steam models do not have an airflow

switch.

The airflow switch operation is controlled by the

counterweight position in the shaft. Moving the

counterweight either increases or decreases airflow

switch sensitivity. The counterweight should be

adjusted so the disc moves away from the cabinet

when the lint panel is opened 1.5 inches (38.1 mm) with

a full load. Adjust the airflow switch as follows:

1. Load the tumbler. This adjustment is much faster

to make with one person opening lint panel in

front and another adjusting the counterweight in

the rear of tumbler.

2. Temporarily tape down the lint panel safety

switch located behind the upper right corner of

the lint panel.

3. Start the tumbler. Open the lint panel 1.5 inches

(38.1 mm). The airflow disc should move away

from the cabinet, opening the switch contacts and

shutting off the heat system. This indicates

proper operation and proper adjustment.

4. If switch is not opening as described in step 3, it

should be adjusted so it is MORE sensitive.

Depress the spring clip and move counterweight

toward disc. Retest by opening lint panel and

continue moving counterweight toward disc until

switch operates as described in step 3.

5. If switch opens BEFORE lint panel is opened the

proper distance, step 3, it should be adjusted so it

is LESS sensitive. Depress the spring clip and

move counterweight away from the disc. Retest

by opening lint panel and continue moving

counterweight away from disc until switch

operates as described in step 3.

IMPORTANT: Remove tape from lint panel switch.

WARNING

To reduce the risk of fire due to

inadequate airflow, the airflow switch

must be adjusted to operate per the

instructions in this manual.

W674