To connect electrical service to the tumbler – Alliance Laundry Systems TMB795C User Manual

Page 44

Advertising
background image

Electrical Requirements

M414905

42

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

To Connect Electrical Service To
The Tumbler

The following steps outline the procedure for

connecting the electrical service to the tumbler.

NOTE: The wiring diagram is located in the

junction or contactor box.

1. Install a circuit breaker as close to the tumbler as

possible. If more than one tumbler is being

installed, a disconnect switch or circuit breaker

should be provided for each. This will make it

possible to disconnect each tumbler for

maintenance purposes.

2. Connect the conduit-encased leads to the disconnect

switch, or circuit breaker. Connect the wire leads

to the appropriate labeled terminal on the terminal

block. The ground wire must be connected to the

ground connection as shown in Figure 21.

3. Check the electrical service phase sequence

(three phase only) as follows:

a. Energize the electrical service (on reversing

tumblers, ensure nonreversing is selected) and

momentarily start the tumbler. Check the

direction of the cylinder rotation. If the

cylinder rotates clockwise (viewed from the

front), the phase sequence is correct. If the

cylinder rotates counterclockwise, proceed

with step b.
NOTE:When viewed from the front, the

fan should rotate clockwise on 50 and 75

Pound models and counterclockwise on

F75 models.

b. Disconnect and reverse any two service leads

on the terminal block.

Advertising