Alliance Laundry Systems TMB795C User Manual

Page 30

Advertising
background image

Installation

M414905

28

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Figure 12

How to Change Burner Orifice Size

1. Disconnect electrical power from tumbler. Close

gas shut-off valve to tumbler. Refer to Figure 11.

2. Remove spud holder.

Johnson G96 Gas Valve – Unscrew spud holder

nut near gas valve. Remove the burner orifice(s)

from spud holder. Refer to Figure 12.

3. Install the new, correct burner orifice(s). Refer to

Figure 13 and Table 1. Torque each to 9 – 10 Nm.

4. Reinstall spud holder assembly to gas valve,

making certain burner orifice(s) are in line with

burner tube opening. Refer to Figure 13.

5. Commission tumbler for use.

NOTE: Blank burner orifices are Part No.

M400995.

TMB1527N

1

Burner

8

Anti-Torque Ring

2

Gas Valve

9

Manifold Pipe

3

Regulator Plate

10

Spud Holder

4

Gasket

11

Pressure Tap

5

Plate

12

Burner Orifice

6

Regulator Cap

13

Burner Tube Openings

7

Spud Holder Nut

1

10

9

8 7

6

5

4

3

2

11

13

12

Advertising