Electrical Requirements

M414905

46

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

75 Pound Gas and Steam Models

Refer to Table 8 and Table 9.

NOTE: Wire size and breaker ratings were

obtained from the Canadian Electrical Code for

75 C. wire and are intended for use as a guideline

only. Electrical connections should be made by a

qualified electrical contractor in accordance with

all applicable local and national requirements.

NOTE: Electrical specifications below are subject

to change without notice. Always refer to product

serial plate for most current specifications of

product being installed.

NOTE: Use copper conductors only.

NOTE: Connect to individual branch circuit.

NOTE: 3 Phase Only – Each tumbler must be

connected to its own individual branch circuit

breaker, not fuses, to avoid the possibility of “single

phasing” and causing premature failure of the

motor(s).

Serial Plate Rating

Terminal Block

Connections

Required

Serial Plate Amps

Recommended Circuit

Nonreversing

Reversing

Breaker

Rating

Wire Size

AWG (mm

2

)

120V/60Hz/1ph

L1, Neutral and ground

13.8

N/A

20A – 1 pole

12 (3.31)

200-208V/60Hz/1ph

L1, Neutral and ground

7.6

N/A

15A – 1 pole

14 (2.08)

200-208-240V/60Hz/

1ph

L1, L2 and ground

7.6

N/A

15A – 2 pole

14 (2.08)

230-240V/50Hz/1ph

L1, Neutral and ground

6.7

7.0

15A – 1 pole

14 (2.08)

200-208V/60Hz/3ph

L1, L2, L3 and ground

3.8

4.3

10A – 3 pole

14 (2.08)

200V/50Hz/3ph

L1, L2, L3 and ground

3.5

4.5

10A – 3 pole

14 (2.08)

240V/60Hz/3ph

L1, L2, L3 and ground

3.8

4.3

10A – 3 pole

14 (2.08)

230-240V/50Hz/3ph

L1, L2, L3 and ground

3.5

4.9

10A – 3 pole

14 (2.08)

380V/50 or 60Hz/3ph

L1, L2, L3 and ground

1.8

2.1

10A – 3 pole

14 (2.08)

400-415V/50Hz/3ph

L1, L2, L3 and ground

1.8

2.1

10A – 3 pole

14 (2.08)

440V/60Hz/3ph

L1, L2, L3 and ground

1.9

2.1

10A – 3 pole

14 (2.08)

460-480V/60Hz/3ph

L1, L2, L3 and ground

1.9

2.1

10A – 3 pole

14 (2.08)

N/A = Not Applicable

Table 8

F75 Gas Models Only

Serial Plate Rating

Terminal Block

Connections

Required

Serial Plate Amps

Recommended Circuit

Nonreversing

Reversing

Breaker

Rating

Wire Size

AWG (mm

2

)

200-208V/60Hz/3ph

L1, L2, L3 and ground

N/A

6.3

15A – 3 pole

14 (2.08)

240V/60Hz/3ph

L1, L2, L3 and ground

N/A

6.3

15A – 3 pole

14 (2.08)

460-480V/60Hz/3ph

L1, L2, L3 and ground

N/A

3.1

10A – 3 pole

14 (2.08)

N/A = Not Applicable

Table 9