Single drop timer – Alliance Laundry Systems TMB795C User Manual

Page 53

Advertising
background image

51

M414905

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Single Drop Timer

NOTE: The following information is for

models with an SD control suffix only.

Power-Up Mode

When power is applied to the tumbler, the IN USE

light flashes factory status information. Following this,

the control goes into READY Mode (light off) or RUN

Mode if power was interrupted during a cycle (light

on, time remaining unchanged).

Ready Mode

In READY Mode (light off), the control waits for the

vend to be satisfied. When vend is satisfied the control

goes into START Mode.

Start Mode

In START Mode (light on), the vend has been satisfied

but the start button has not been pressed. Time

remaining in the cycle will not change until the start

button is pressed. When the start button is pressed the

machine goes into RUN Mode.

Run Mode

In RUN Mode (light on), the machine is running a

cycle and the time remaining is counting down. When

time remaining counts down to zero, the control goes

into READY Mode.

Setting Dry Time Dipswitches

To change the dry time on the tumbler, combinations

of dipswitches can be set on the control.
There are eight dipswitches on the tumbler control.

The first six switches are used to program the amount

of additional heat time given for each coin pulse. The

additional drying time is added to the factory default

minimum heat time of one minute. A valve of 1 to 64

minutes of additional drying time is available for each

coin drop pulse.
The last two switches are used to program the amount

of additional cool down time. The additional cool

down time is added to the factory default minimum

cool down time of 1 minute. A value of 1 to 3

additional minutes is available. The control is shipped

from the factory programmed with 1 minute of

minimum heat time, preset with 7 additional minutes

of drying time (dipswitches 1, 2 and 3 in ON position)

and 1 minute of minimum cool down time for a total

time of 9 minutes for a coin pulse. For dipswitch

settings Refer to Table 12.
The control reads the dipswitch settings at power-up.

The control must be powered down to change the

dipswitch settings.
To change the time for a coin pulse, the desired dry

time dipswitches must be set to ON position. All other

dipswitches must be in OFF position.