Before placing tumbler into service, Warning – Alliance Laundry Systems TMB795C User Manual

Page 26

Advertising
background image

Installation

M414905

24

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Before Placing Tumbler into Service

1. Remove or open all panels and check accessible

bolts, nuts, screws, terminals and fittings for

tightness.

2. Check belt tension and adjust if necessary. Refer

to Adjustments section.

3. Replace all panels and guards.
4. Turn on electrical supply to tumbler.
5. Open the supply valve for gas or steam heated

tumblers.

6. After performing the previous checks, start the

tumbler by pressing START. (Refer to the

Operating Manual for detailed instructions.)

Release the start button and open the loading

door. The cylinder should stop rotating within

seven seconds after the door is opened a

maximum of 2 inches (51 mm). If it does not,

adjust the loading door switch. Refer to

Adjustments section.

7. Gas Tumblers: Start the tumbler and check the

burner flame. Adjust the air inlet shutter as

required. Refer to Adjustments section.

IMPORTANT: The electronic ignition system will

attempt to light the gas by sparking for the “trial

for ignition” period. If gas does not ignite within

this period, the ignition control will go into a safety

lockout and the valve will no longer open until the

control is reset. It may be necessary to retry several

times to bleed air from the gas lines. To reset, open

and close the loading door and restart tumbler.

If lockout condition persists, check that the manual

gas shut-off valve is in the ON position and that the

gas service is properly connected. If condition still

persists, remove tumbler from service.

8. Load the cylinder with a full load of clean rags

and run to remove oil or dirt from cylinder.

9. Check the airflow switch operation refer to

Adjustments section. The heating systems should

shut off when the lint panel is opened a

maximum of 1.5 inches (38 mm).
The airflow switch operation may be affected by

shipping tape still in place, lack of make-up air,

or an obstruction in the exhaust duct. These

should be checked and the required corrective

action taken before attempting to adjust the

airflow switch. To adjust the airflow switch, refer

to Adjustments section.

10. Wipe out the cylinder using an all-purpose

cleaner or detergent and water solution. Refer to

Figure 10.

Figure 10

If the tumbler does not meet ANY of the listed

requirements, remove tumbler from use. Refer to

Removing Tumbler from Service section.

Prepurge

Time

(seconds)

Trial for

Ignition

(seconds)

Reset

Lockout

Condition

By:

Australia

18

5

Open loading

door

CE

18

10

Press reset

button behind

front access

panel

All Others

1 – 3

10

Open loading

door

T452I

Do not operate tumbler if airflow switch is

faulty. An explosive gas mixture could

collect in tumbler if airflow switch does not

operate properly.

W407

WARNING

T452I

Advertising