1 rx power and receiving frequency, Rx power and receiving frequency – Boonton PIM 31 User Manual User Manual

Page 90

Advertising
background image

90


13.3.1 Rx Power and Receiving Frequency

The following measurements have to be executed with
utmost care:

If too much power is applied to the PIM31 test system, the
receiver module will be damaged

If the RF output power of the PIM31 is accidentally switched
ON, it

.

will damage the Signal Generator

.

In order to measure the accuracy and frequency selectivity of the receiver, the
following components and

• Signal Generator

Install the test set-up as shown:

• Set the PIM31 to Field Mode
• Set frequencies of carrier signal 1 and 2 to the start and end frequency of

the provided frequency band.

• Set the power level of each signal to 20 dBm (100mW) – with ALC: ON
• Set the Filter bandwidth of the PIM31 to 1.2 kHz (default).

To avoid damage, RF Power of the PIM 31 must be OFF