Maximum Time
The meaning of this field is dependent on the Control type. If the Control type is Send Data then this field means
how often the message is transmitted out from the DVC controller and DVC80. If the Control type is Receive
Data then this field means how often the message is expected to be received. Error indications will occur if
these times are exceeded.
Range: 10ms to 10seconds.

PDU Format (PF)
The PF field identifies one of two PDU formats able to be transmitted (PDU1 or PDU2). PDU Formats are
described in the SAE J1939/21, Section 3.3.
Range: 0 to 255

PDU Specific (PS)
The meaning of this field is dependent on the value of PF. If the PF value is between 0 and 239 (PDU1), this PS
field contains a destination address. If the PF field is between 240 and 255 (PDU2), the PS field contains a
Group
Extension (GE) to the PDU Format. The Group Extension provides a larger set of values to identify messages,
which can be broadcast to all ECUs on the network.
Range:
0 to 255
Priority
The Priority field assigns how important the message is to be processed. The highest priority is 0 and lowest
priority is 7. (This field is not needed when “Control” type is “Receive Data”)
Range: 0 to 7
Data Length
Data Length is the length of the message in bytes.
Range: 1 to 8
Byte # Name
Byte Name is the suffix of the name to access a byte in Bubble Logic. For instance
eec1.status_eec1 would be used to access byte 1 of the defined message EEC1
shown here.
Range: 16 Alpha/Numeric characters only with no spaces.

DVC80 Program Variables
Name.NORSP

True when a message has not been received in the

“Maximum

Time”

period


Name.Byte#Name

Set/Get the current value of that byte of the J1939

CAN

message

Range: 0 to 255

Name.disable

True will prevent messages from being sent. This variable

defaults to false.

Name.srcaddr

Message that are sent from the DVC7/10 will have this number as the J1939

source address. If this value is 0 (the default) the source address will be the

DVC80

macid

value.

Message Example
Message Name:

EEC1

Control

Receive Data from ECM

Maximum Time: 50ms Engine Speed Dependent
PDU Format (PF)

240

PDU Specific (PS) 4

PGN = (PF*256)+PS