Page | 50

Digital Input

Name Description

Range

Name

1

Set/Get the state of the switch

False or Off, True or
On

Name.RealRPM

The Unsigned Integer Value of the RPM. For Pulse
inputs Only

0 to 9999

Name.PulseTimeout

Get/Set Pulse Timeout for Loss of Signal

0 to 65535

Name.PulsesPerRev

Get/Set Pulses Per Revolution

0 to 9999

Name.Counter

Get/Set Unsigned Integer Value of the Counter.
Pulse inputs Only

0 to 65535

Name.LOS

Loss of Signal flag set after time out. For Pulse
inputs Only

False (Pulses ok),
True (No Pulse Input)


Universal and Analog Input

Name Description

Range

Name

1

Get 0 to 100% regardless of direction

0% to 100%

(Min Volts to Center
Volts)
NameLo

1

Get 0 to 100% of Min to (Center - Deadband)
only if Center is enabled

0% to 100%

(Center Volts to Max
Volts)
NameHi

1

Get 0 to 100% of (Center + Deadband) to Max
only if Center is enabled

0% to 100%

Name.Dir

Get the Upper or Lower Side of the Analog
Input only if Center is enabled.
Lower Side voltage is lower than the Upper
Side

False (Lower Side), True
(Upper Side)

Name.RawVolts

Volts or mAmps (ma = universal input ma
select)

0 to 1023 * Scale

2

Name.RefVolts

Reference Volts = RefVolts * .00489

0 to 1023

Name.RampVolts

Ramped Volts = RampVolts * Scale Factor

0 to 1023 * Scale

2

Name.MinVolts

When Name = 0% (i.e. Center not enabled)

0 to 1023 * Scale

2

Name.MaxVolts

When Name = 100%

0 to 1023 * Scale

2

Name.MinLimit

Threshold for Name.MinF

0 to 1023 * Scale

2

Name.MaxLimit

Threshold for Name.MaxF

0 to 1023 * Scale

2

Name.RefMinLimit

Threshold for Name.MinRF

0 to 1023 * Scale

2

Name.RefMaxLimit

Threshold for Name.MaxRF

0 to 1023 * Scale

2

Name.CenterVolts

Where Center Volts

0 to 1023 * Scale

2

Name.Deadbandv

Plus and minus volts about CenterVolts

0 to 1023 * Scale

2

NameX.RampUp

RampUp * .01 = Time Min to Max (Seconds)

0.0 to 65.00 s

NameX.RampDown

RampDown * .01 = Time Max to Min (Seconds)

0.0 to 65.00 s

NameX

Where NameX = NameLo, NameHi if Center is
enabled NameX = Name if Center is not
enabled


Name.MinF

Status Flag set if Voltage is less than Min Limit

False (ok), True (Outside
Limit)

Name.MaxF

Status Flag set if Voltage is greater than Max
Limit

Range: False (ok), True
(Outside Limit)

Name.MinRF

Status Flag set if Voltage is less than
Reference Min Limit

False (ok), True (Outside
Limit)

Name.MaxRF

Status Flag set if Voltage is greater than
Reference Max Limit

False (ok), True (Outside
Limit)