16 program variables – High Country Tek DVC80 User Manual

Page 49

Advertising
background image

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools

Page | 49




























Using the input fields on the right side of the
window shown you can reverse the LED’s
display side and set the Power On period for the
DVC7.











3.16 Program Variables

Program variables are identifiers that are used
by your application program to refer to specific input values and to control the operation of a specific output.
This section is divided into various subsections according to Input/Output category. The following gives the
definition of all the program variables:

LED STATE

MEANING

Off

No PWMs are active.

RED

>>

GREEN

The greatest PWM % 0 -> 100%

Flashing

GREEN

PWM or High Side output Open circuit detected

Flashing

RED

PWM or High Side output Short circuit detected


LED3: Error / System Enable / Module Ready

LED STATE

MEANING

On

RED

Unrecoverable error

On

Yellow

System Enable active (Power cycle required to reset)

On

GREEN

Module

Ready

Flashing

RED

Low voltage (<8.5vdc) into DVC7

LED4: Error Code

LED STATE

MEANING

Off No

errors

On

RED

PWM1 Open or Short detected

On

GREEN

PWM2 Open or Short detected

Flashing

Yellow

High Side Open or Short detected

Flashing

RED

Application defined blink codes when blinkcode
variable > 0.

Advertising
This manual is related to the following products: