P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools

Page | 99

Range: 1 - 5 = Memory Bucket # (1 – 5) Active
DVC70.AlarmState
Range: 1 – 5 = Alarm State for Memory Bucket 1 – 5
DVC70.PercentUsed
Possible Values: 50%, 60%, 70%, 80%, 90%, 95%, 98%, and 100%
DVC70.MinSec
Bits: bits 0 – 6 (Seconds) – 0 - 59

bits 8 – 15 (Minutes) – 0 - 59

DVC70.DayHours
Bits: bits 0 – 4 (Hours) – 0 - 23

bit 5 PM or AM – 0 or 1

bit 6 12 or 24 hour clock – 0 or 1

bits 8 – 15 (Day of the Week) – 1 - 7
DVC70.MonthDate
Bits: bits 0 – 5 (Date) – 1 - 31

bits 8 – 13 (Month) – 1 - 12

DVC70.Year
Bits: bits 0 – 7 (Year) – 00 - 99
Memory Bucket Name

Range: 1 Name per Memory Bucket
Memory Bucket Name.VarName1 – 10 (Trend only)
Range: 1 Name per Variable
Memory Bucket Name.VarName1 – 5 (Event or Fault) – the application programmer uses this variable to set up
the Message to be displayed if the event becomes true and to set up the Scaling factor
Range: 1 Name per Variable
SF1 – 12

Possible Values: SF1 = 0 = None

SF2 = 4096 = 1:1

SF3 = 8192 = -1 Volt to 1 Volt

SF4 = 12288 = 0 Volts to 5 Volts

SF5 = 16384 = 0 Volts to 10 Volts

SF6 = 20480 = 4 ma to 20ma

SF7 = 24576 = Supply Volts

SF8 = 28672 = True / False

SF9 = 32768 = On / Off

SF10 = 36864 = 0.1

SF11 = 40960 = 0.01 (s)

SF12 = 45056 = 0.001


Memory Bucket Name.Data1 – 5 (Event or Fault)
Range: 1 Data point for each Variable (1 – 5)