For the DVC hardware PI Loop regulating current, this is the P value
Range: 0 to 655.00
Current I
For the DVC hardware PI Loop regulating current, this is the I value
Range: 0 to 655.00
Dither Amp

How much current above and below set point to dither
Range: 0 to 100%
Dither Hz
The frequency setting of the dither
Range: 1Hz to 500Hz
High Side # Name
This will be the access word for the High Side Output. Set this ON or OFF in your application.
Range: 16 Characters with no spaces. Valid characters are A-Z, a-z, 0-9, and "_".
Rules:
The first character cannot be a number
Compiler Keywords or other Names already in use are not valid.
Min Cur
The Min Coil current setting for Coil A in Single and Dual Coil selections corresponding to 0% PWM
Range: 0 to 3 A
Note the text on how to set this value in your application described in the Max Cur section below.
Max Cur

The Max Coil current setting for Coil A in Single and Dual Coil selections corresponding to 100% PWM
Range: 0 to 3 A

With release 4.7 of the BIOS, Programming Tool and Program Loader Monitor, the Coil Current Gain constants
are available to allow you to set the Max Cur or Min Cur in your application. Coil current gains are the factors
the BIOS uses to calculate the actual current through a coil given all of the variances in the current sense
circuits internal to the DVC controller. The Coil current gain constants are loaded into the individual DVC
controller’s flash memory when the unit is tested at HCT’s manufacturing facility. For each output group there is
one coil gain for current ranges 0-3amps and another one for low current ranges or 0-90ma. The variable
names are HC_Coil_Gain_OG1 and LC_Coil_Gain_OG1, HC_Coil_Gain_OG2 and LC_Coil_Gain_OG2 and
HC_Coil_Gain_OG3 and LC_Coil_Gain_OG3 for output groups 1,2 and 3 respectively.

Setting the Max Cur and Min Cur in your application is done with statements like:
OutputGroupName.maxcura = (Current_in_milliamps * 100) / HC_Coil_Gain_OG1
OutputGroupName.mincura = (Current_in_milliamps * 100) / HC_Coil_Gain_OG1

For Dual Coils the second coils current setting is accomplished with statements like:
OutputGroupName.maxcurb = (Current_in_milliamps * 100) / HC_Coil_Gain_OG1
OutputGroupName.mincurb = (Current_in_milliamps * 100) / HC_Coil_Gain_OG1
Ramp Down
When the Enable Current Ramps is selected, Ramp Down is the ramp from Max to Min Current.
Ramps are applied for all current / PWM% changes.
Range: 0.0 to 65.00 s
Ramp Up

When ramps are checked, Ramp Up is the Ramp from Min to Max Current.
Ramps are applied for all current / PWM% changes.
Range: 0.0 to 65.00 s
Output Selection
This is where the user configures the output type

Range:
Dual Coil High Side