High Country Tek DVC80 User Manual

Page 48

Advertising
background image

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools

Page | 48

LED STATE

MEANING

Off

There is no power applied to the module.

On

GREEN

The module is operating in a normal condition.

Flashing

GREEN

Device is in standby state. May need servicing.

On

RED

Module has an unrecoverable fault.

Flashing

RED

Recoverable

fault.

Flashing

RED

/

Green

This DVC7 was loaded with an application that was
compiled for a DCV10 or DVC5. The DVC7 is not
operational in this condition. Recompile the application
as a DVC7 type and load that application.



LED1 and LED2: Network Status

LED STATE

MEANING

Off

There is no J1939 device (or other DVCs) in the
project.

On

GREEN

J1939/CAN Bus communication has been established.

Flashing

GREEN

J1939/CAN Bus device in project but communication
has not been established. Flash 2 times in 2 seconds.

On

RED

The device has detected an error that has rendered it
incapable of communicating on the network.

Flashing

RED

The J1939 communication is in a timed-out state.
Flash 2 times in 2 seconds.


Normal Operation

Length: Until the next power cycle

Summary:
LED1 shows Network status
LED2 shows max PWM
LED3 error, System Enable or module ready
LED4 is the error code if any set by the blinkcode or open/short detection


LED1: Network Status (Same as Power On)

LED STATE

MEANING

Off

There is no J1939 device (or other DVCs) in the
project.

On

GREEN

J1939/CAN Bus communication has been established.

Flashing

GREEN

J1939/CAN Bus device in project but communication
has not been established. Flash 2 times in 2 seconds.

On

RED

The device has detected an error that has rendered it
incapable of communicating on the network.

Flashing

RED

The J1939 communication is in a timed-out state.
Flash 2 times in 2 seconds.


LED2: PWM Status