background image

P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools

Page | 53

from 100% to 0%)

Name.Frequency

Set PWM frequency

0 to 1000 for 0 to 100hz

Name.Dutycycle

Ser PWM dutycycle

0 to 1023 for 0 to 100%

Name.Freqerror

Returns error 1 = Frequency error,
2 means duty cycle error

HSEvenName

Set the Bang-bang Coil to On or Off

Off, On

HSEven#Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil
Short]

HSEven#Name.Open

Get the Coil Flag for Open Status

Off [Coil Ok], On [Coil
Open]

HSOddName

Set the Bang-bang Coil to On or Off

Off, On

HSOdd#Name.OpenDisable

Set the Disable Coil Open Detection

0 [Enabled], 1 [Disabled]

HSOdd#Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil
Short]

HSOdd#Name.Open

Get/Set the Coil Flag for Open Status

Off [Coil Ok], On [Coil
Open]

Name.Cur

Current actual * CurGain = amps

0 – 3.5 amps

Name.RampCur

Current ramped Currend*CurGain= amps

0 – 3.5 amps

Name.CurErr

Current Error = RampCur – Cur

16 Signed Integer

Name.CurSumErr

Current Error accumulated over time

0 – 65535

Name.CurP

Current Proportional Term Constant “P”

0 – 255

Name.CurI

Current Proportional Term Constant “I”

0 – 255

Name.MinCurA

Minimum Current Coil A *.001 = amps

0 – 3.5 amps

Name.MaxCurA

Maximum Current Coil A *.001 = amps

0 – 3.5 amps

Name.Config

Configuration Word – Output, Process,
Coil


Output Group Selected as PWM Disabled

Name Description

Range

HSEvenName

Set the Bang-bang Coil to On or Off

Off, On

HSEven#Name.OpenDisabl
e

Set the Disable Coil Open Detection

0 [Enabled], 1 [Disabled]

HSEven#Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil
Short]

HSEven#Name.Open

Get the Coil Flag for Open Status

Off [Coil Ok], On [Coil
Open]

HSOddName

Set the Bang-bang Coil to On or Off

Off, On

HSOdd#Name.OpenDisabl
e

Set the Disable Coil Open Detection

0 [Enabled], 1 [Disabled]

HSOdd#Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil
Short]

HSOdd#Name.Open

Get/Set the Coil Flag for Open Status

Off [Coil Ok], On [Coil
Open]


Enable Process PI Variables
The Name field is the Low-Side name. The default variable name is replaced with the specified name.

Name Description

Range

Name.Setpoint

The desired % set point position for the
output

0 to 100%

Name.Feedback

The % feedback position for the output

0 to 100%

Name.ProErr

Error = Set point – Feedback

16 bit signed integer

Name.ProSumErr

Error accumulated over time

0 – 65535

Name.ProP

Process Proportional Term Constant “P”

0 – 255