Page | 52

Output Group Selected as Single Coil High-Side

Name Description Range
Name

Set the state Current Target or
Process in percentage of min to max
current
0 = 0 Current, .1% = Min Current,
and 100% = Max Current

0% to 100%

Name.Enable

Set the PWM to 0 or enable the
PWM

True [PWM Enabled], False
[PWM = 0]

Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil Short]

Name.Open

Get the Coil Flag for Open Status

Off [Coil Ok], On [Coil Open]

Name.Rampup

Set the ramp up rate (time to travel
from 0% to 100%)

0.0 to 65.00 s

Name.Rampdown

Set the ramp down rate (time to
travel from 100% to 0%)

0.0 to 65.00 s

HSEvenName

Set the Bang-bang Coil to On or Off

Off, On

HSEven#Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil Short]

HSEven#Name.Open

Get the Coil Flag for Open Status

Off [Coil Ok], On [Coil Open]

HSOdd#Name.OpenDisable

Set the Disable Coil Open Detection

0 [Enabled], 1 [Disabled]

HSOdd#Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil Short]

HSOdd#Name.Open

Get/Set the Coil Flag for Open
Status

Off [Coil Ok], On [Coil Open]

Name.Cur

Current actual * CurGain = amps

0 – 3.5 amps

Name.RampCur Current

ramped

Currend*CurGain=

amps

0 – 3.5 amps

Name.CurErr

Current Error = RampCur – Cur

16 Signed Integer

Name.CurSumErr

Current Error accumulated over time

0 – 65535

Name.CurP

Current Proportional Term Constant
“P”

0 – 255

Name.CurI

Current Proportional Term Constant
“I”

0 – 255

Name.MinCurA

Minimum Current Coil A *.001 =
amps

0 – 3.5 amps

Name.MaxCurA

Maximum Current Coil A *.001 =
amps

0 – 3.5 amps

Name.Config

Configuration Word –Output,
Process, Coil


Output Group Selected as Single Coil Low-Side

Name Description

Range

Name

Set the state Current Target or Process in
percentage of min to max current
0 = 0 Current, .1% = Min Current, and
100% = Max Current

0% to 100%

Name.Enable

Set the PWM to 0 or enable the PWM

True [PWM Enabled],
False [PWM = 0]

Name.Short

Get the Coil Flag for Short Status

Off [Coil Ok], On [Coil
Short]

Name.Open

Get the Coil Flag for Open Status

Off [Coil Ok], On [Coil
Open]

Name.Rampup

Set the ramp up rate (time to travel from
0% to 100%)

0.0 to 65.00 s

Name.Rampdown

Set the ramp down rate (time to travel 0.0 to 65.00 s