10ms to the DVC10 while Mail Inputs are sent to the DVC50 every 20ms. Direct memory transfers will complete
every 40ms.

The DVC50 I/O configuration screen is very similar to the DVC10’s
screen with the addition of the Name, MAC ID and IO Assignment fields. Also note the different number of
Analog/Pulse Inputs and that only six function curves are provided instead of eight.

The Name field is used to identify this DVC50 module and serves as the prefix for DVC50 IO names.

The MAC ID is the CAN Bus address for this module. This field must be specified and be unique in order for the
modules to communicate via the CAN Bus.

Digital Inputs
The DVC50 Digital Input Screen is laid out like the DVC10 Digital Input screen and is used in the same manner.
All of the 8 inputs are sinking (i.e. externally powered).

Analog Inputs
The DVC50 Analog Input screen is laid out like the DVC10 Analog Input screen and is used in the same
manner. All of the inputs have a corresponding +5vdc reference output pin and signal common or ground pin.

Analog / Pulse Inputs
The DVC50 Analog / Pulse input screen is laid out like the DVC10
Universal Input screen except that there is no Voltage Range selection
for the DVC50 (see the DVC50 Hardware Users Guide for information on
input voltage limits). Otherwise, it is used in the same manner as the
Universal Input screen for the DVC10. All of the inputs have a
corresponding +5vdc reference output pin and signal common or ground
pin.

Output Groups
The DVC50 Output Group screen is laid out like the DVC10 Output
Group screen and is used in the same manner.

Input / Output Functions
The DVC50 Input / Output Functions screen is laid
out like the DVC10 Input / Output Functions screen
and is used in the same manner.

IO Assignments
The IO Assignments screen allows the user to
quickly set up Input to Output relationships including
the use of Function Curves as well as to map and
name Mail variables.

Output Groups
There are three Output Groups screens. By using
the pull down menus on the right, you may assign
different available inputs to control the listed output
variables. Available selections depend on the setup
of the output group (i.e. Dual Coil High Side etc.).
The DVC7/10 Bubble logic code must control
assignments that do not have their box checked.