Evc/epc controller, With sae j1939 interface – High Country Tek epc, Electronic Pump Controller - A Multi-Function SAE J1939 Compatible Module User Manual

Page 19

Advertising
background image

023-00354-Rev1.6

evc/epc User Manual

19

Copyright © High Country Tek, Inc.

– 2013

evc/epc Controller

With SAE J1939 Interface

Ramp Up (1 to 65,000 Mini Seconds)

– Determines the time for Output A or B to ramp UP from minimum to

maximum current.

Ramp Down (1 to 65,000 Mini Seconds)

– Determines the time for Output A or B to ramp Down from maximum to

minimum current.

Coil A&B PWM Hz (33 to 500Hz)

– This is the PWM or Dither frequency according to the valve spec. (Sun

cartridges are 140Hz).

Ignore Open (ON/OFF)

When Ignore Open

is “ON” and Current Feedback is “ON”, the evc/epc will

not

declare an error when the output

duty cycle reaches 100%.

When Ignore Open is “OFF” and Current Feedback is “ON”, the evc/epc will declare an error when the output
duty cycle reaches 100%.

When Current Feedback is “OFF”, Ignore Open does not have any effect.