Controller specification, Controller mounting information, Evc/epc controller – High Country Tek epc, Electronic Pump Controller - A Multi-Function SAE J1939 Compatible Module User Manual

Page 5: With sae j1939 interface, 114mm, 2x ø5

Advertising
background image

023-00354-Rev1.6

evc/epc User Manual

5

Copyright © High Country Tek, Inc.

– 2013

evc/epc Controller

With SAE J1939 Interface

Controller Specification

48.5mm

125mm

5

8

m

m

4

3

9

10 11 12

2

1

6

5

7

8

114mm

CL

2x Ø5

Controller Mounting Information

Mount controller in an easily accessible
location.

Mount controller to a flat, cool surface.

If mounting to a hydraulic product, allow at
least a 2mm air gap underneath the unit.

Use BOTH mounting holes with correct
hardware.

DO NOT mount controller with connector
facing UP if possible.

Housing Type

HCT encapsulated block

Power Supply Voltage 9 to 32VDC

(Absolute maximum)

Current Consumption

Valve current + 50mA Quiescent

(Max)

Command Inputs

SAE J1939

2x switched inputs

(ON/Off)

2x analog inputs:
One with

(0-5V, 0-10V, 4-20mA)

One with

(0-5V, 0-10V, Pulse or Freq. - 3 to

30KHz)

Input Impedance

Voltage & Freq. inputs = 100k

4-20mA input = 100

Outputs

2x 3A proportional PWM

(Sourcing)

(

Short circuit protection and open circuit alert

)

1x 5VDC ±10%

(Regulated voltage @ 250mA)

PWM Dither Freq.

Software adjustable - 33 to 500Hz

Module Connector

DTF15-12PB, 12-way Male

Communication

Mini-B USB standard

Housing Material

Black, Polycarbonate

Encapsulation

Flameproof epoxy resin

Mounting

2x No.8

(5mm)

screws

Temperature Range

-40 to +85ºC

(Operational)

-60 to +90ºC

(Storage)

NEMA/IP Rating

NEMA 6P/IP67

Advertising