evc/epc Controller

With SAE J1939 Interface

SAE J1939

Set Point A or B % and Set Point RPM

A SAE J1939 message can set the demand for coil A and B.


Measured RPM

The evc/epc controller can accept an SAE J1939 message containing the measured engine RPM on PGN: 0xF004
(61444) Source Address (SA): 0x00.

Timeout

The box is red when the SAE J1939 message has timed out indicating a bus, connection or data error.

Outputs for coil A and B will ramp to the default settings according to the “Command & Error” page.

If “Recover from loss of signal" is “ON”, the outputs will resume normal operation when a valid SAE J1939

message is received. The box becomes green.

MAC ID

– Displays and allows changing the MAC ID. It is the network address for this specific evc/epc.

Report Analog Values

– When “ON”, it will transmit the values of the analog inputs on SAE J1939 Bus. It does not

force to change the settings.