Analog values message parameter values, Evc/epc controller, With sae j1939 interface – High Country Tek epc, Electronic Pump Controller - A Multi-Function SAE J1939 Compatible Module User Manual

Page 41

Advertising
background image

023-00354-Rev1.6

evc/epc User Manual

41

Copyright © High Country Tek, Inc.

– 2013

evc/epc Controller

With SAE J1939 Interface

Parameter Values

Coil n Set point

Data Length

2 Bytes

Resolution

0.00152903 %/bit, 0 offset

Data Range

0% to 100%

Operational Range

0 to 100%

Coil n Current

Data Length

2 Bytes

Resolution

1mA/bit, 0 offset

Data Range

0 to 65535mA

Operational Range

0 to 3000mA

RPM

Data Length

2 Bytes

Resolution

0.125 rpm/bit, 0 offset

Data Range

0 to 8,031.875 rpm

Operational Range

0 to 8,031.75 rpm

Analog Values Message

Start Position

Length

Parameter Name

1

1 Byte

Always = 2 (Analog Value)

2-3

2 Bytes

Command Input Value (volts x100 or mA x100)

4

1 Byte

0 = Command Volts, 1 = Command mA

5-6

2 Bytes

Pulse Input volts x100

7

1 Byte

Always = 0

8

1 Byte

Always = 0