evc/epc Controller

With SAE J1939 Interface

Pulse/AIN 2 Settings

Pulse Input Selections (Analog or Pulse)

– Select

analog to use this input as analog input 2 for dual
valve control or select pulse to use this input as the
pulse input for anti-stall function.

0-5V, 0-10V & ±1V (Enabled/OFF)

– Select the

voltage range that matches the analog input signal.

The ±1V only applied to Pulse input.

For anti-stall function, match the voltage range to
the Pulse Pick UP. The signal can be 0-5VDC, or
0-10VDC, or ±1VDC.

Pulses per revolution PPR - (1 to 65535)

– Enter

the pulse per revolution of the speed sensor.

Maximum displayed RPM (1 to 65535)

– Visual only - scales the RPM gauge on the Dashboard.

Keep this value near the maximum RPM to assure the resolution and accuracy.

RPM slow Set-Point or Max Load RPM (1 to 65535)

– The set-point where coil A current starts to reduce in Anti-

Stall or HP limit modes.

RPM stop Set-Point or No Load RPM (1 to 65535)

– The set-point where coil A current reaches 0 in Anti-Stall or

HP limit modes. If auto-reverse is ON, reverse cycle will start at this rpm.