evc/epc Controller

With SAE J1939 Interface

Command & Error Settings

Analog Input Active (On/Off)

– Enables/Disables

the command analog input.

Analog Center Active (On/Off)

When enabled, the

“Pot Center Voltage” becomes the zero demand point.

Coil A is driven from the center voltage to the max voltage and coil B is driven from the center voltage to the min

voltage

This setting is used in Dual Coil Valve Control only. The

Coil Selection Active” switch is automatically turned

OFF when the Center Active

is “ON”.

Coil Selection Active (On/Off)

When the input is High, (+5V to Supply Volts) coil B is active and when Low (0V to 2.5V) coil A is active.

This feature allows the full command resolution on coil A and B.

As an example, it is used in the applications where a reciprocating action is triggered by a single high-low input.

Pot Center Error Detection at Initial Turn On

When ON, the module verifies the analog input is in the center deadband range before enabling the output(s)

after the initial power up.

Once the command is centered, the outputs will be enabled.

This safety feature ensures that the system will NOT immediately go to the previous settings after cycling the

power.