evc/epc Controller

With SAE J1939 Interface

Dead band

The Dead band can only be used when the Analog Center Active

is “ON”.

Dead band is split one half above, one half below the center point.

0.2VDC means coil A output current starts at 2.6VDC, coil B output current starts at 2.4VDC.

Pot Maximum

It sets the max command input to have the maximum current.

If the command input is > POT Maximum + the Command Margin, the evc/epc will declare an error and the

outputs go to the default settings.


Pot Center

– Sets the value of the center of the dead band.


Pot Minimum

It sets the min command input to have the minimum current.

If the command input is < Minimum - the Command Margin, the evc/epc will declare an error and the outputs go

to the default settings.


Reference voltage is 5V ±10% @ 250mA.

HCT has a manual command potentiometer

– part number 999-10205 that outputs 0.5-4.5VDC when connected to

a +5VDC user voltage.

Auto Calibrate Pot Input

Calibrate the command limits

– i.e. joystick or foot pedal etc.

When the button is clicked, a box will appear with

instructions.

Adjust the input from full High to full Low, and then adjust to

the neutral or crossover point.

“OK” to save the values.