Status message format, Evc/epc controller, With sae j1939 interface – High Country Tek epc, Electronic Pump Controller - A Multi-Function SAE J1939 Compatible Module User Manual

Page 40

Advertising
background image

023-00354-Rev1.6

evc/epc User Manual

40

Copyright © High Country Tek, Inc.

– 2013

evc/epc Controller

With SAE J1939 Interface

Status Message Format

Transmission Cycle Time

100mS

Data Length

8

Data Page

0

PDU Format

255

PDU Specific

Module ID + 128

Priority

3

Parameter Group Number

65409 Through 65535

(FF81 Through FFFF)



Status Message

Start Position

Length

Parameter Name

1

1 Byte

Always = 1 (Status)

2.1

1 bit

Command Input Error

2.2

1 bit

Reference Voltage Error

2.3

1 bit

Pulse Input LOS

2.4

1 bit

Power Supply High

2.5

1 bit

Power Supply Low

2.6

1 bit

Coil A Msg Timeout

2.7

1 bit

Coil B Msg Timeout

2.8

1 bit

RPM Msg Timeout

3.1

1 bit

not used

3.2

1 bit

Reverse Cycle Active

3.3

1 bit

Digital Input 1 State

3.4

1 bit

Digital Input 2 State

3.5

1 bit

Coil A Short

3.6

1 bit

Coil A Open

3.7

1 bit

Coil B Short

3.8

1 bit

Coil B Open

4.1

1 bit

Process A Ramping

4.2

1 bit

Process B Ramping

4.3

1 bit

Command Input Not Centered

4.4

1 bit

Reverse Cycle Retry Timeout

4.5

1 bit

System in Startup Mode

4.6

1 bit

System in Shutdown Mode

4.7

1 bit

not used

4.8

1 bit

not used

5-6

2 Bytes

Coil A Current (mA)

7-8

2 Bytes

Coil B Current (mA)


Advertising