Wesley BC-620-4CA User Manual

Page 118

Advertising
background image

114

Curtis 1234/36/38 Manual,

OS

11

Table 5 TROUBLESHOOTING CHART, continued

PROGRAMMER LCD DISPLAY

CODE

EFFECT OF FAULT

POSSIBLE CAUSE

SET/CLEAR CONDITIONS

8 — DIAGNOSTICS & TROUBLESHOOTING

27

Digital Out 7 Overcurrent

1. External load impedance on Digital

Set: Digital Output 7 (pin 20) current

Digital Output 7 driver

Output 7 driver (pin 20) is too low. exceeded 15 mA.

will not turn on.

Clear: Remedy the overcurrent cause

and use the VCL function

Set_DigOut()

to turn the driver on again.

28

Motor Temp Hot Cutback

1. Motor temperature is at or above

Set: Motor temperature is at or above the

Reduced drive torque.

the programmed Temperature Hot

Temperature Hot parameter setting.

setting, and the requested current is

Clear: Bring the motor temperature

being cut back.

within range.

2. Motor Temperature Control Menu

parameters are mis-tuned.

3. See Monitor menu » Motor:

Temperature and » Inputs: Analog2.

4. If the application doesn’t use a motor

thermistor, Temp Compensation

and Temp Cutback should be

programmed Off.

29

Motor Temp Sensor Fault

1. Motor thermistor is not connected

Set: Motor thermistor input (pin 8) is at

MaxSpeed reduced (LOS,

properly.

the voltage rail (0 or 10V).

Limited Operating Strategy),

2. If the application doesn’t use a motor Clear: Bring the motor thermistor input

and motor temperature

thermistor, Motor Temp Sensor

voltage within range.

cutback disabled.

Enable should be programmed Off.

3. See Monitor menu » Motor:

Temperature and » Inputs: Analog2.

31

Coil1 Driver Open/Short

1. Open or short on driver load.

Set: Driver 1 (pin 6) is either open or

ShutdownDriver1.

2. Dirty connector pins.

shorted. This fault can be set only when

3. Bad crimps or faulty wiring.

Main Enable = Off.

Clear: Correct open or short, and cycle driver.

31

Main Open/Short

1. Open or short on driver load.

Set: Main contactor driver (pin 6) is

ShutdownMotor;

2. Dirty connector pins.

either open or shorted. This fault can be

ShutdownMainContactor;

3. Bad crimps or faulty wiring.

set only when Main Enable = On.

ShutdownEMBrake;

Clear: Correct open or short, and cycle driver

ShutdownThrottle;

FullBrake;

ShutdownPump.

32

Coil2 Driver Open/Short

1. Open or short on driver load.

Set: Driver 2 (pin 5) is either open or

ShutdownDriver2.

2. Dirty connector pins.

shorted. This fault can be set only when

3. Bad crimps or faulty wiring.

EM Brake Type = 0.

Clear: Correct open or short, and cycle driver.

32

EMBrake Open/Short

1. Open or short on driver load.

Set: Electromagnetic brake driver (pin 5)

ShutdownEMBrake;

2. Dirty connector pins.

is either open or shorted. This fault can

ShutdownThrottle;

3. Bad crimps or faulty wiring.

be set only when EM Brake Type > 0.

FullBrake.

Clear: Correct open or short, and cycle driver.

33

Coil3 Driver Open/Short

1. Open or short on driver load.

Set: Driver 3 (pin 4) is either open or

ShutdownDriver3.

2. Dirty connector pins.

shorted.

3. Bad crimps or faulty wiring.

Clear: Correct open or short, and cycle driver.

34

Coil4 Driver Open/Short

1. Open or short on driver load.

Set: Driver 4 (pin 3) is either open or

ShutdownDriver4.

2. Dirty connector pins.

shorted.

3. Bad crimps or faulty wiring.

Clear: Correct open or short, and cycle driver.

Advertising