Wesley BC-620-4CA User Manual

Page 127

Advertising
background image

Curtis 1234/36/38 Manual,

os 11

Fig. A-2

Power section

topology.

Heavy busbars connect the IMS modules to the external motor connec-

tion studs. A bank of power capacitors keeps DC bus levels stable during high
frequency MOSFET switching and also reduces EMI on the external B+ and
B- cables.

Motor currents and motor speed and direction are the primary feedback

signals used in the motor control algorithms. Accurate Hall sensors detect the
motor currents; they do this by sensing the flux created by the motor currents
on the U and V motor output busbars where they pass through the capacitor
board on their way to the external motor connections. Motor speed and direc-
tion are simultaneously sensed by a quadrature-type speed encoder mounted
on the motor shaft.

APPENDIX A: THEORY OF OPERATION

A-3

Advertising