Wesley BC-620-4CA User Manual

Page 14

Advertising
background image

10

Curtis 1234/36/38 Manual,

OS

11

12 Switch 6

Generic switch input #6.

Sw_6

13 Coil Return

This is the coil return pin

for all the contactor coils.

14 Switch 16 / DNC

In the 1234, this is

Sw_16

generic switch input #16.

In the 1236 and 1238,

Do Not Connect.

15 Throttle Pot High

Pot high connection for

a 3-wire throttle pot.

16 Throttle Pot Wiper Pot wiper connection for

Setup_Pot

Throttle_Pot

the throttle pot.

Setup_Pot_Faults

Throttle_Pot_Output

17 Pot2 Wiper

Pot wiper connection for

Setup_Pot

Brake_Pot

the brake pot.

Setup_Pot_Faults

Brake_Pot_Output

18 Pot Low

Common pot low

Pot_Low_Output

connection for the throttle

and brake pots.

19 Digital Out 6

An open collector digital

Set_DigOut

Sw_14

output. Can also be used Clear_DigOut

DigOut6

as a digital input.

Dig6_Output

20 Digital Out 7

An open collector digital

Set_DigOut

Sw_15

output. Can also be used Clear_DigOut

DigOut7

as a digital input.

Dig7_Output

21 CAN Term H

High connection for the

CAN termination jumper.

22 Switch 7

Generic switch input #7.

Sw_7

Typically used as the

Forward switch.

23 CANH

CAN bus high.

Setup_CAN

Setup_Mailbox

Send_Mailbox

etc.

24 Switch 1

Can be used as generic

Sw_1

Analog 1

switch input #1 or as

Analog1_Input

generic analog input #1.

Typically used for

emergency reverse switch

(if applicable).

25 +12V Out

Unregulated low power

Ext_Supply_Current

+12V output.

26 +5V Out

Regulated low power

5_Volts_Output

+5V output.

Ext_Supply_Current

27 Pot2 High

Pot high connection for

a 3-wire brake pot.

2 — INSTALLATION & WIRING:

Low Current Connections

Table 2 Low Current Connections,

cont’d

RELATED

VCL

PIN

NAME

DESCRIPTION

FUNCTIONS

REFERENCES

Yes, this
remains
Brake_Pot
in VCL.

Advertising