Low power outputs

Two control lines on the 1236/38 are available as low power digital outputs.
These are open collector drivers that can only sink current, not source it, and
are intended to drive LEDs or other low current loads connected to the +5V
or +12V external power supplies; see power supply output group specs. Fault
protection will turn off these outputs if output voltage exceeds about 15 V
when the output is On (low output). Both outputs are protected against shorts
to B+ or B-.

These lines can also be used as digital inputs, and are included in that

group as well.

2 — INSTALLATION & WIRING:

I/O Signal Specifications

LOW POWER OUTPUT SPECIFICATIONS

ALLOWED

OUTPUT

PROTECTED

ESD

SIGNAL

NAME

PIN

VOLTAGE

IMPEDANCE

VOLTAGE

TOLERANCE

Digital Out 6

19

0 to 15 V

On: 1 kΩ to B-

- 5 V to

± 8 kV (air

Digital Out 7

20

Off: 134 kΩ

(MaxV + 10 V) discharge)

*

The digital outputs for the 1234 are below, with the high power outputs

.

High power outputs

Seven control lines on the 1234 and five on the 1236/38 can be used as high
power output drivers. One of these, the proportional driver, can be operated in
a current control mode for driving a proportional valve or similar load. Each
output can be independently turned on continuously (low level) or pulse width
modulated to set the average output voltage. These outputs are intended to
drive inductive loads such as contactors and electromagnetic brakes but could
also be used to drive resistive loads if peak current ratings are not exceeded. All
these outputs are protected against shorts to B+ or B-.

These lines can also be used as digital inputs, and are included in that

group as well.

HIGH POWER OUTPUT SPECIFICATIONS

PV

FREQ

-

OUTPUT

PROTECTED

ESD

SIGNAL

NAME

PIN

PWM

CURRENT

UENCY

CURRENT

VOLTAGE

TOLERANCE

Driver 1

6

0 to 100% n/a

200 Hz 2 A max - 0.5 V to

± 8 kV (air

Driver 2

5

duty cycle

3 A max keyswitch discharge)

Driver 3

4

2 A max voltage

Driver 4

3

Prop Driver 2

0 to 2 A 18 kHz

in 607

nominal

steps

Digital Out 6 19

on/off

n/a

n/a 1 A max

Digital Out 7 20

*

On the 1234, the combined current supplied

by all seven output drivers should not exceed 10 A

.