3 — PROGRAMMABLE PARAMETERS:

Motor Temperature Parameters

MOTOR TEMPERATURE CONTROL MENU

ALLOWABLE

PARAMETER

RANGE

DESCRIPTION

Sensor Enable

On/Off

When programmed On, the motor temperature cutback and the motor

MotorTemp_Sensor_Enable

On/Off

temperature compensation features are enabled. This parameter can be

OptionBits3 [Bit 1]

used only if a temperature sensor has been properly configured.

The motor temperature cutback feature will linearly cutback the drive

current from 100% to 0% between the Temperature Hot and Temperature
Max temperatures.

The motor temperature compensation feature will adapt the motor

control algorithms to varying motor temperatures, for improved efficiency
and more consistant performance.

Sensor Type

1–5

Five sensor types are predefined in the software:.

MotorTemp_Sensor_Type

1–5

Type 1 KTY83–122

Type 2 2× Type 1, in series

Type 3 KTY84–130 or KTY84–150

Type 4 2× Type 3, in series

Type 5 PT1000.

Custom sensor types can be set up easily, if none of the five predefined
types is appropriate for your application. Please contact your Curtis
customer support engineer.

Note: The industry standard KTY temperature sensors are silicon

temperature sensors with a polarity band;

the polarity band of a KTY

sensor must be the end connected to I/O Ground (pin 7).

Sensor Temp Offset

-20 – 20 °C

Often the sensor is placed in the motor at a location with a known offset

MotorTemp_Sensor_Offset

-200200

to the critical temperature; the offset can be corrected with this parameter.
The parameter can also be used to correct a known offset in the sensor
itself.

Temperature Hot

0–250 °C

Defines the temperature at which drive current cutback begins.

MotorTemp_Hot

02500

Temperature Max

0–250 °C

Defines the temperature at which drive current is cut back to zero.

MotorTemp_Max

02500

MotorTemp LOS Max Speed 100–3000 rpm When a Motor Temp Sensor Fault (fault code 29) is set, a LOS (Limited
MotorTemp_LOS_Max_Speed

100–3000

Operating Strategy) mode is engaged. The maximum speed is reduced to
the programmed Max Speed in the operating mode (Max_Speed_SpdMx,
Max_Speed_SpdM, Max_Speed_TrqM)

or to the MotorTemp_LOS_Max_

Speed, whichever is lower.