Curtis 1234/36/38 Manual,

OS

11

11

2 3 J U LY 2 0 0 8 D R A F T

2 — INSTALLATION & WIRING:

Low Current Connections

Table 2 Low Current Connections,

cont’d

RELATED

VCL

PIN

NAME

DESCRIPTION

FUNCTIONS

REFERENCES

28 Serial TX

Serial transmit line for

Setup_Serial

display or flash update.

29 Serial RX

Serial receive line for

Setup_Serial

flash update.

30 Analog Output

Low power, low frequency Automate_PWM

PWM6

0–10V analog output.

Put_PWM

Analog_Output

31 Encoder A

Quadrature encoder

Motor_RPM

input phase A.

MotorspeedA

32 Encoder B

Quadrature encoder

Motor_RPM

input phase B.

MotorspeedB

33 Switch 8

Generic switch input #8.

Sw_8

Typically used as the

Reverse switch.

34 CAN Term L

Low connection for the

CAN bus termination

jumper.

35 CANL

CAN bus low.

Setup_CAN

Setup_Mailbox

Send_Mailbox

etc.